Differences

This shows you the differences between two versions of the page.

err:1a1361 [2011/05/10 09:28] (current)
Line 1: Line 1:
 +This error indicates that the Infiniband link is still in the Init state, and has not yet received a PortInfo MAD from the subnet manager requesting a transition to the Armed state.
 +
 +Things to try:
 +
 +  * Check that your subnet manager is rescanning the fabric sufficiently frequently.  If you are using the [[http://www.openfabrics.org/downloads/management/|OpenSM]] subnet manager, you can force a rescan with the command:<code>    killall -HUP opensm</code>
 
err/1a1361.txt · Last modified: 2011/05/10 09:28 (external edit)